Detection unit BDRG-47R

Function: 
measurement of gamma ray absorbed dose level in air in conditions of emergency and post-accident including accidents beyond design basis. 

Application:
is applied by monitoring service at sites with atomic power plants as well as at other sites related to obtaining, reprocessing and using of radioactive materials.

 

 

 

 

 

Specifications

Detector type Ion chamber
Measurement range, Gy/h 1,0*10-4 – 1,0*105
Energy range, MeV 0,06 – 8,0
Working temperature range, oС
for detection unit;
for BI-43R
From 0 to +220
From 0 to +60
Protection level IP67
Irradiation stability for detector block and standpipe, Gy/h 106
Input current, VA 50
Time to failure, h 30000
Equipment Detector block;
Standpipe with access line
Measuring unit BI-43R
Dimensions, mm
Detector block
Standpipes
BI-43R
150х290;
154х1600;
270х403х194
Weight, kg
BI-43R
Detector block
Standpipes
8;
3;
60
Output type Encoded in RS-485 interface over two independent channel